• CAN Communication
CAN InterfaceISO 11898-2, Terminals (CAN_H, CAN_L,CAN_GND)
ProtocolsCAN 2.0A and 2.0B (ISO 11898-2)
Connector Type3-pin removable screw terminal x1
Termination ResistorDip switch selector for 120 Ω terminal resistor
Transfer RateUp to 1 Mbps
System Delay150 ns
Isolation Protection2 kV
ESD ProtectionSupports 15 kV
Transmission DistanceMax 2 km (depends on the data rate and the protocol used)
NoteThe transmission distance is limited by the signal rate, as indicated in the ISO 11898-2 standard.
LED IndicatorsPWR1, PWR2, Fiber TX, Fiber RX
• Fiber Communication
Connector TypeST (multi-mode) fiber ports
Support Cable50/125, 62.5/125, or 100/140 μm (multi-mode)
Wavelength850 nm
TX OutputMulti-mode (> -5 dBm)
Rx SensitivityMulti-mode (-20 dBm)
• Physical Characteristics
HousingMetal
Dimensions30.3 x 70 x 115 mm (1.19 x 2.76 x 4.53 in)
• Environmental Limits
Operating TemperatureStandard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 85°C (-40 to 185°F)
Storage Temperature-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity5 to 95% (non-condensing)
• Power Requirements
Input Voltage12 to 48 VDC dual power inputs for redundant power
Power ConsumptionICF-1170I: 221 mA @ 12 V
Alarm Contact: 1 relay output with current carrying of 1 A @ 24 VDC
Voltage Reversal ProtectionProtects against V+/V- reversal
Over Current Protection1.1 A (protects against two signals shorted together)
• Standards and Certifications
SafetyUL 508, EN 60950-1
EMCCE, FCC
EMIEN 55022 Class A, FCC Part 15 Subpart B Class A
EMSEN 61000-4-2 (ESD) Level 4,
EN 61000-4-3 (RS) Level 2,
EN 61000-4-4 (EFT) Level 4,
EN 61000-4-5 (Surge) Level 3,
EN 61000-4-6 (CS) Level 2,
EN 61000-4-8 (PFMF) Level 3
FreefallIEC 60068-2-32
Green ProductRoHS, CRoHS, WEEE
• MTBF (mean time between failures)
Time792,085 hrs
DatabaseTelcordia (Bellcore), GB
• Warranty
Warranty Period5 years