EDS-316 - Switch Ethernet Não Gerenciável, 16X 10/100Baset(X)
Moxa
Model: EDS-316
Product ID: 1826
Product SKU: 1826
EDS-316 - Switch Ethernet Não Gerenciável, 16X 10/100Baset(X)

EDS-316 - Switch Ethernet Não Gerenciável, 16X 10/100Baset(X)

Estoque: 0 Marca: MoxaModelo:EDS-316 Referência: EDS-316

Carregando...

Features and Benefits

Download Moxa 2015 IES brochure!

  • Relay output warning for power failure and port break alarm
  • Broadcast storm protection
  • Transparent transmission of VLAN tagged packets
  • -40 to 75°C operating temperature range (T models)

Introduction

The EDS-316 are 16-port Ethernet switches that provide an economical solution for your industrial Ethernet connections. The built-in relay warning function alerts network engineers when power failures or port breaks occur, and the switches are designed for harsh industrial environments. The switches comply with FCC, TÜV, UL, and CE standards, and come in two model types. Standard operating temperature range models (0 to 60°C) and wide operating temperature range models (-40 to 75°C). Both models undergo a 100% burn-in test to ensure that they fulfill the special needs of industrial automation control applications. The EDS-316 switches can be installed easily on a DIN-rail or in a distribution box.

 

• TechnologyStandardsIEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3x for Flow ControlProcessing TypeStore and ForwardFlow ControlIEEE 802.3x flow control, back pressure flow control• Switch PropertiesMAC Table Size4 KPacket Buffer Size1.25 Mbit• InterfaceFiber Ports100BaseFX ports (SC/ST connector)RJ45 Ports10/100BaseT(X) auto negotiation speed, Full/Half duplex mode, and auto MDI/MDI-X connectionDIP Switches• Port break alarm mask
• Enable/disable broadcast storm protectionLED IndicatorsPWR1, PWR2, FAULT, 10/100M (TP port), 100M (fiber port)Alarm Contact1 relay output with

 

current carrying capacity of 1 A @ 24 VDC• Optical FiberTable• Power

 

RequirementsInput Voltage12/24/48 VDC (9.6 to 60 VDC), redundant dual inputsInput CurrentEDS-316: 0.27 A @ 24 V
EDS-316-M/S/MM/SS/MS: 0.44 A @ 24 VOverload Current Protection1.6 AConnection1 removable 6-pin terminal blocksReverse Polarity ProtectionPresent• Physical CharacteristicsHousingMetal, IP30 protectionDimensions80.1 x 135 x 105 mm (3.15 x 5.31 x 4.13 in)Weight1140 gInstallationDIN-rail mounting, wall mounting (with optional kit)• Environmental LimitsOperating TemperatureStandard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)Storage Temperature-40 to 85°C (-40 to 185°F)Ambient Relative Humidity5 to 95% (non-condensing)• Standards and CertificationsSafetyUL 508, UL 60950-1, CSA C22.2 No. 60950-1, EN 60950-1Hazardous LocationUL/cUL Class 1 Division 2 Groups A/B/C/D,
ATEX Zone 2 Ex nA nC IIC T4 GcEMIFCC Part 15 Subpart B Class A, EN 55022 Class AEMSEN 61000-4-2 (ESD) Level 3, EN 61000-4-3 (RS) Level 3,
EN 61000-4-4 (EFT) Level 3, EN 61000-4-5 (Surge) Level 3,
EN 61000-4-6 (CS) (EDS-305/308: Level 2; EDS-309/316: Level 3)MarineDNV, GLShockIEC 60068-2-27FreefallIEC 60068-2-32VibrationIEC 60068-2-6NotePlease check Moxa’s website for the most up-to-date certification status.• MTBF (mean time between failures)Time257,000 hrsDatabaseMIL-HDBK-217F, GB 25°C• WarrantyWarranty Period5 yearsDetailsSee www.moxa.com/warranty

Deixe seu comentário e sua avaliação







- Máximo de 512 caracteres.

Clique para Avaliar


  • Avaliação:
Enviar
Faça seu login e comente.

Características


  • Área: Ethernet Industrial