Moxa - EDS-305-S-SC - Switch Ethernet Não Gerenciável, 4X 10/100Baset(X), 1X 100Basefx Monomodo, Conector Sc
Moxa
Model: EDS-305-S-SC
Product ID: 1798
Product SKU: 1798
New In stock />
EDS-305-S-SC - Switch Ethernet Não Gerenciável, 4X 10/100Baset(X), 1X 100Basefx Monomodo, Conector Sc

EDS-305-S-SC - Switch Ethernet Não Gerenciável, 4X 10/100Baset(X), 1X 100Basefx Monomodo, Conector Sc

Estoque: 1 Marca: MoxaModelo:EDS-305-S-SC Referência: EDS-305-S-SC

Na compra desse produto ganhe 990Watts
Carregando...
/ 1
Simulador de Frete
- Simulador de Frete

Features and Benefits

Download Moxa 2015 IES brochure!

  • Relay output warning for power failure and port break alarm
  • Broadcast storm protection
  • Transparent transmission of VLAN tagged packets
  • -40 to 75°C operating temperature range (T models)

Introduction

The EDS-305/308 are 5-port and 8-port Ethernet switches that provide an economical solution for your industrial Ethernet connections. The built-in relay warning function alerts network engineers when power failures or port breaks occur, and the switches are designed for harsh industrial environments, such as in hazardous locations (Class I, Div. 2/ATEX). The switches comply with FCC, TÜV, UL, and CE standards, and come in two model types. Standard operating temperature range models (0 to 60°C) and wide operating temperature range models (-40 to 75°C). Both models undergo a 100% burn-in test to ensure that they fulfill the special needs of industrial automation control applications. The EDS-305/308 switches can be installed easily on a DIN-rail or in a distribution box.

ss sss

• Technology
StandardsIEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3x for Flow Control
Processing TypeStore and Forward
Flow ControlIEEE 802.3x flow control, back pressure flow control
• Switch Properties
MAC Table Size1 K
Packet Buffer Sizen/a (EDS-305), 512 kbit (EDS-308)
• Interface
Fiber Ports100BaseFX ports (SC/ST connector)
RJ45 Ports10/100BaseT(X) auto negotiation speed, Full/Half duplex mode, and auto MDI/MDI-X connection
DIP SwitchesPort break alarm mask
LED IndicatorsPWR1, PWR2, FAULT, 10/100M (TP port), 100M (fiber port)
Alarm Contact1 relay output with current carrying capacity of 1 A @ 24 VDC
• Optical Fiber
Table
• Power Requirements
Input Voltage24 VDC (12 to 48 VDC), redundant dual inputs
Input CurrentEDS-305: 0.13 A @ 24 V
EDS-305-M/S: 0.17 A @ 24 V
EDS-308: 0.13 A @ 24 V
EDS-308-M/S: 0.21 A @ 24 V
EDS-308-MM/SS: 0.26 A @ 24 V
Overload Current ProtectionEDS-305, EDS-305-M, EDS-305-S, EDS-308: 1.1 A
EDS-308-M/S/MM/SS: 1.6 A
Connection1 removable 6-pin terminal blocks
Reverse Polarity ProtectionPresent
• Physical Characteristics
HousingMetal, IP30 protection
Dimensions53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in)
Weight790 g
InstallationDIN-rail mounting, wall mounting (with optional kit)
• Environmental Limits
Operating TemperatureStandard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity5 to 95% (non-condensing)
• Standards and Certifications
SafetyEDS-305 Series: UL 508, UL 60950-1, CSA C22.2 No. 60950-1
EDS-308: UL 508, UL 60950-1, CSA C22.2 No. 60950-1, EN 60950-1
Hazardous LocationUL/cUL Class 1 Division 2 Groups A/B/C/D,
ATEX Zone 2 Ex nA nC IIC T4 Gc
EMIFCC Part 15 Subpart B Class A, EN 55022 Class A
EMSEN 61000-4-2 (ESD) Level 3, EN 61000-4-3 (RS) Level 3,
EN 61000-4-4 (EFT) Level 3, EN 61000-4-5 (Surge) Level 3,
EN 61000-4-6 (CS) (EDS-305/308: Level 2; EDS-309/316: Level 3)
MarineDNV, GL
ShockIEC 60068-2-27
FreefallIEC 60068-2-32
VibrationIEC 60068-2-6
NotePlease check Moxa’s website for the most up-to-date certification status.
• MTBF (mean time between failures)
TimeEDS-305 Series: 422,000 hrs
EDS-308 Series: 255,000 hrs
DatabaseMIL-HDBK-217F, GB 25°C
• Warranty
Warranty Period5 years

Deixe seu comentário e sua avaliação







- Máximo de 512 caracteres.

Clique para Avaliar


  • Avaliação:
Enviar
Faça seu login e comente.

Características


  • Área: Ethernet Industrial